Energy lntelligence PDU for Data Centers
Optional Accessories
Environment Sensors
ATEN provides various environment sensors to work with NRGence
PDU. The sensors enable you to get status feedback
on temperature, humidity or differential pressure.
Cable Holders
For added safety, use ATEN Lok-U-Plug cable holders to secure the cables from your attached devices in place on the Energy
PDU unit. Use only the ATEN Lok-U-Plug cable holders that have been specifically designed to work with the Energy PDU.
Using any other kind of cable securing device could be highly dangerous.
Part No. Sensor
EA1140 Temperature
EA1240 Temperature / Humidity
EA1340
Differential Pressure /
Temperature
Part No. Cable Holder
2X-EA07 Lok-U-Plug (10 PCS per pack) Patent Pending!
Corporate Headquarters
ATEN International Co., Ltd.
3F., No.125, Sec. 2, Datong Rd., Sijhih District.,
New Taipei City 221, Taiwan
Phone: +886-2-8692-6789 Fax: +886-2-8692-6767
www.aten.com E-mail: [email protected]
U.S.A. Subsidiaries:
ATEN Technology Inc.
19641 DaVinci, Foothill Ranch, CA 92610, U.S.A
Phone: +1-949-428-1111 Fax: +1-949-428-1100
www.aten-usa.com E-mail: [email protected]
Japan Subsidiary :
ATEN Japan Co., Ltd.
ATEN Bldg. 8-4, Minami-senjyu 3-chome, Arakawa-ku,
Tokyo 116-0003 Japan
Phone: +81-3-5615-5810 Fax: +81-3-3891-3810
www.atenjapan.jp E-mail: [email protected]
Korea Subsidiary :
ATEN Korea.,Ltd.
B-303, Gabeul Great Valley, 60-5, Gasan-dong,
Geumcheon-gu, Seoul, Korea; 153-801
Phone: +82-2-467-6789 Fax: +82-2-467-9876
www.aten.co.kr E-mail: [email protected]
China Subsidiary :
ATEN China Co., Ltd.
18/F, Tower A, Horizon International Tower,
No.6, Zhichun Road,
Haidian District, Beijing, China 100088
Phone: +86-10-5255-0110 Fax: +86-10-8296-1318
www.aten.com.cn E-mail: [email protected]
Taiwan Subsidiary :
Atech Peripherals, Inc.
6F., No.133, Sec. 2, Datong Rd., Sijhih District.,
New Taipei City 221, Taiwan
Phone: +886-2-8692-6969 Fax: +886-2-8692-6926
www.aten.com.tw E-mail: [email protected]
Belgium Subsidiary :
ATEN Infotech N.V.
Mijnwerkerslaan 34, 3550 Heusden-Zolder, Belgium
Phone: +32-11-531543 Fax: +32-11-531544
www.aten.be E-mail: [email protected]
U.K. Subsidiary :
ATEN U.K. Limited
229 Berwick Avenue, Slough, SL1 4QT, U.K.
Phone: +44-1753-539-121 Fax: +44-1753-215-253
www.aten.co.uk E-mail: [email protected]
ATEN New Jersey Inc.
155 Pierce Street, Somerset, NJ 08873, U.S.A
Phone: +1-732-356-1703 Fax: +1-732-356-1639
www.aten-usa.com E-mail: [email protected]
ATEN New Jersey Inc.
155 Pierce Street, Somerset, NJ 08873, U.S.A
Phone: +1-732-356-1703 Fax: +1-732-356-1639
www.aten-usa.com E-mail: [email protected]
© Copyright 2012 ATEN
®
International Co., Ltd.
ATEN and the ATEN logo are trademarks of ATEN International Co., Ltd. All rights reserved. All other trademarks are the property of their respective owners. Printed 02/2012 V1.0
Energy Management Software
eco Sensors
eco Sensors software has been developed to work with NRGence
power distribution units (PDUs) to effectively increase the efficiency
of data center power usage. With the use of dynamic Rack Cooling Index (RCI) and Return Temperature Index (RTI) by zone, eco
Sensors software, in conjunction with sensor-enabled eco PDUs, gives you the means to assess, diagnose and estimate how much
energy you can save. Following the suggestions generated by the sensor-enabled system allows you to optimize energy usage to save
energy without harming your IT equipment’s reliability.
Automatic discovery of all PE devices within the same intranet
Remote real-time power measurement and monitoring
PDU level current / voltage / power dissipation / power consumption
Outlet ON / OFF / Recycle status
Remote real-time power outlet management*
Power outlet ON / OFF / Cycle switching by outlet
User-defined outlet level delays for sequential power up
Current / Voltage / Power Dissipation / Power Consumption threshold level setting
User access assignment for every outlet
Name assignment to individual outlets
Remote real-time environment sensor monitoring
Temperature / Temperature + Humidity reading / Temperature + Differential Pressure
Temperature and Humidity threshold level setting
Plotting/Monitoring of all PE devices
Add data center server racks
Add PE devices for each server rack
Manage device/device outlet status for each plot
Offers essential data center indices including RCI( Rack Cooling Index ), RTI ( Return Temperature Index ),
RHI ( Rack Humidity Index ), RPI ( Rack Pressure Index ), RAI ( Rack Airflow Index )
Power analysis report for optimizing data center energy management – including power usage, power load,
power cost, CO2 cost, power capacity and trend
Exceed threshold alert through SMTP and System log
10240 line event log
System log provision
Two-level password security
*
Not all functions are supported by all NRGence
PDU. Please see www.aten.com for more details.
Hardware Requirement
Operating System Windows XP / Windows Server 2003 and later
CPU 2.0 GHz Dual Core
Display Larger than 1024x768
Memory 2GB
Disk 300GB
Network 10/100/1000 Mbp Ethernet
System Parameter
Max PDU number 1000
Data Center Layout 45x30
Max Rack Number 500
Max Zone Number 20
Power Report Data 3 years
Real Time Dashboard Data 1 hours
eco PDU Sensor Probes Server Storage
Normal
1
1
2 3 4 5
1 5 10 15 20 25
5
A
6 7 8 9
10
Warning CriticalUnreachable
IT Oce
Report Title: Sales Department IT Power Analysis
Daily Report: 2011/1/1 – 2011/5/5 by Bill Li
IT Power Usage Chart
1/1 2/2 3/3 4/4 5/5 1/1 2/2 3/3 4/4 5/5
kWH
6
- Sales 2
- Sales 3
- Sales 1
4
2
IT Power Load Chart
kWH
6
Sales
4
2
IT Inventory List in Report
No. Name Peak Watts Peak CO2e/Hrs Yearly Power Cost Yearly CO2e Cost Location
01 Web Server 3 1.8 kg 1200 600 L25
02 Log Server 6 3.6 kg 3600 1800 L27
Temperature Sensor
Dierential
Pressure
Sensor
Internet/
LAN
Internet/
LAN
IT Oce
Setup
Power Distribution
Space saving 0U rack mount design
IEC or NEMA outlet models
Daisy chain up to 15 additional stations for up to 384 outlets
2 x 7 segment front panel LED shows Station and Outlet IDs
3 x 7 segment LED shows current, voltage or power dissipation at
PDU level
Remote users can monitor outlet status via web pages on their
browsers
Safe shutdown support
Separate power for the unit's own power and its power outlets –
the user interface is still accessible even when an overload condition
trips the devices' circuit breakers
Remote Access
Remote power control via TCP/IP and a built in 10/100 Ethernet port
Out of Band operation via modem access
Network Protocols: TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP,
ARP, NTP, DNS, Telnet, auto sense, Ping
eco PDU Power Management software – eco Sensors
Supports SNMP Manager V3
IPv6 support
Operation
Local and Remote power outlet control (On, Off, Power Cycle)
by individual outlets and outlet groups
Outlet group support at the PDU and Daisy-chain levels – the
same action can be performed on a specified group of outlets at
the same time
Supports redundant power management via daisy chaining and
outlet groups
On/Off scheduling for individual outlets and outlet groups. Power
management tasks can be scheduled on a daily, weekly, monthly,
or user-specified times basis
Supports multiple power control methods – Wake on LAN, System
After AC Back, Kill the Power
Power-on sequencing - users can set the power on sequence and
delay time for each outlet to allow equipment to be turned on in
the proper order
Easy setup and operation via a browser-based user interface
Multibrowser support (IE, Firefox, Chrome, Safari)
Telnet and SSH access for text menu configuration and outlet
level switching / monitoring
Local console access support
Java GUI AP program provided for non-browser connectivity
RTC support to keep the timer running during times of no power
Up to 64 user accounts - up to 32 concurrent logins
Management
Power status measurement at PDU and outlet levels
LED indicators for current, voltage, power dissipation,
temperature, and humidity at the PDU and outlet levels
Current, voltage, power dissipation, and energy consumption
displayed in a browser based UI for monitoring at the outlet,
group, PDU, and daisy-chain levels
Alert threshold notification for selected events (On, Off, Recycle,
Failure, etc.), via audio alarm and blinking LEDs (locally), SMTP,
SNMP trap notification, and digital output
Environment monitoring – supports external temperature /
temperature & humidity sensors for rack temperature and
humidity monitoring
Current, voltage, power dissipation, energy consumption,
temperature, and humidity threshold level setting
Auto-Ping pings a device to determine its status, if the ping
test fails after a set amount of time- it automatically takes
an action assigned
Current and voltage threshold setting
Naming support for outlets and outlet groups
User outlet access assignment on an outlet-by-outlet basis
Event logging and syslog support
Integration with ALTUSEN CC2000 Management software
and KVM devices
Supports Management Information Base (MIB) files for
SNMP
API for 3rd party software centralized control integration
Upgradeable firmware – daisy chained stations receive the
upgrade via the daisy chain bus
Multilanguage support
Security
Three-level password security
IP/MAC Filter for enhanced security protection
Strong security features include strong password protection
and advanced encryption technologies – 128 bit SSL
Remote authentication support: RADIUS, TACACS+, LDAP,
LDAPS and Active Directory
PE98224/PE98324
eco PDU
PE98224
NEMA
:
20A (derated 16A) ;
IEC: 16A 3 Phase
24 Outlets
0U
PE98324
NEMA
:
30A (derated 24A) ;
IEC: 32A 3 Phase
24 Outlets
0U
Model Nominal Input Power
# of Bank x Nominal
Output Power
# of Outlet Socket x
Type
Switching
Capability
Metering
Capability
Regulatory Approval
PE98224B
20A, 346 – 415V
NEMA L22-20P 3LNG Plug
3 x 20A
200 – 240V
3 x IEC 320 C19 +
21 x IEC 320 C13
Per Outlet Per Outlet
FCC, TUV-CB
*
, TUV-UL
*
,
TUV-PSE
*
PE98224G
16A, 346 – 415V IEC309
3PNPE Plug
3 x 16A
200 – 240V
3 x IEC 320 C19 +
21 x IEC 320 C13
Per Outlet Per Outlet CE, TUV-CB
*
PE98324B
30A, 346 – 415V
NEMA L22-30P 3LNG Plug
6 x 16A
200 – 240V
6 x IEC 320 C19 +
18 x IEC 320 C13
Per Outlet Per Outlet
FCC, TUV-CB
*
TUV-UL
*
, TUV-PSE
*
PE98324G
32A, 346 – 415V IEC309
3PNPE Plug
6 x 16A
200 – 240V
6 x IEC 320 C19 +
18 x IEC 320 C13
Per Outlet Per Outlet
CE
TUV-CB
*
*
Ready for compliance.
The specification and pictures are subject to change without notice.
NRGence Catalog_cs3-2.indd 5-8 2012/4/17 11:29:58 AM