ATEN PN5212 User Manual Page 1

Browse online or download User Manual for Power distribution units (PDUs) ATEN PN5212. PN5212/PN5320/PN7212/PN7320

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
PN5212/PN5320/PN7212/PN7320
FEATURES
Power Over the NET™
Power Distribution Units
Benefits
With PDU/Outlet level metering, IT administrators can easily monitor the
current, voltage, and power consumption status of all connected IT equipment
via a browser-based UI. With the addition of temperature and humidity sensors,
even the status of the rack environment can be monitored from just about
anywhere in the world.
By simply clicking a button on the browser-based UI, administrators can power
control the connected devices with ease. There is no longer any need to move
around the server room turning equipment on and off. Outlet level remote
switching ensures that the server room operates smoothly.
p1
p2 p3 p4 p5
ALTUSEN Power Over the NET™ products are Power Distribution Units that offer outlet level control combined with
remote access to give IT administrators the ability to power control devices attached to the unit from practically any
location via a TCP/IP connection. With support for power status measurement, PDUs enable administrators to
monitor the current, voltage and power consumption of their IT equipment, either at the PDU or outlet level,
minimizing the power cost of running their equipment; and ensuring high levels of system availability for server
rooms of all sizes.
The ALTUSEN PDU is highly suitable for server rooms or data centers with high-density server deployments. It
features a space-saving 0U design that allows it to be mounted vertically on the outside of the rack, resulting in a
more efficient use of server room space, and the elimination of the usual cable clutter. With NEMA or IEC outlet
support and with amperage capacity (20A or 30A for NEMA; 16A or 32A for IEC) , the PDU delivers plenty of power
to the rack, which means you can safely connect a larger number of IT devices than you could with ordinary power
units.
A measuring feature, coupled with a threshold alarm, keeps you informed of the operating status of all your
attached equipment. Warning messages regarding triggered alarms can be sent via an SMTP server or SMS via the
unit's Digital Output port. PDUs also provide sensor ports for temperature and humidity monitoring and threshold
alarm message notification. IT administrators are able to easily and conveniently monitor and power control
connected devices remotely if necessary by means of a browser-based UI, thereby minimizing maintenance costs
and ensuring 24/7 reliability for their server room operations.
ALTUSEN Power Distribution Units can be daisy-chained to manage even more devices, so your server room
management can expand in step with your company's growth. In a daisy-chained installation, administrators can
remotely monitor and control the power status of a server that has a dual power supply from a single portal, by
connecting its power cords to the outlets of separate level units (so they can receive power from separate sources).
For ease of management, when PDUs are deployed in conjunction with other ALTUSEN products*, administrators
can access them all from the same user interface.
When a PDU is integrated in a CC (Control Center Over the NET™) management software installation, the power
outlet of an IT device can be associated with its KVM port and displayed on the same CC web page. This allows IT
administrators to completely control an IT device from a single user interface. In addition, to provide the highest
possible system integration, the Intelligent PDU offers an API to support third-party management software.
*KVM Over the NET™
Remote Monitoring
Outlet Switching
The PDU permits server room administrators to set custom thresholds for
current, voltage, power consumption, humidity, and temperature. When
levels exceed the user defined thresholds, designated recipients can receive
alarm notifications via SMTP email, SNMP traps, or SMS sender (connected to
the Digital Output port). An audio alarm can also sound and lights with blink
at the local site. Necessary steps can be taken to avoid equipment damage
due to such things as circuit overload – reducing mean time to recovery and
minimizing loss.
The PDU supports external, environment sensors that allow administrators to
monitor temperature and humidity remotely. IT administrators can set
environment thresholds to identify critical value and take preventive actions
before a system failure occurs – thereby helping to obtain the highest degree
of availability for all mission-critical equipment.
Combining with ALTUSEN's CC (Control Center Over the NET™)
management software gives IT administrators the advantages of centralized
control over the entire Power Over the NET™ installation, as well as all other
Over the NET™ products from a single user interface. By associating the KVM
port, serial port and power outlet of an IT device, all the ports can be
presented on the same web page for convenient access and management. In
addition, a free API is included with the PDU that provides the ability to
integrate the unit into your existing IT applications and tools.
The ALTUSEN PDU can be integrated with multiple ALTUSEN devices to
provide a single interface point – the switch’s interface – allowing IT
administrators to control servers or serial devices at the same time as they
control their power management. For KVM switches that support the Power
Association function, a KVM port can be associated with a power outlet. If
the connected server has a dual power supply the KVM port can be
associated with two outlet ports and the operation of both power supplies
can be synchronized.
The ALTUSEN PDU supports daisy-chaining and outlet groups to provide
redundant power management. Equipment with dual power supplies can be
assigned to outlet groups for convenient control. Since up to 15 additional
units can be daisy chained from the master unit, IT administrators can
connect a server’s power cords to different units - each of which is connected
to a separate power source - for failsafe operation. Management efficiency is
also increased, since the power status of both outlets can be monitored and
controlled from the same portal.
Early Warning
Notification
Environment Monitoring
Centralized
Management
ALTUSEN Product
Integration*
Redundant Power
Management
p6
Specification
Inlet/Outlet Chart
Optional Equipment
Power Distribution
Maximum Amps/Outlet:
NEMA 20A / 12 outlets (PN5212/PN7212); 30A/ 20 outlets (PN52320/PN7320)
IEC 16A / 12 outlets (PN5212/PN7212); 32A/ 20 outlets (PN5320/PN7320)
Space saving 0U rack mount design
IEC or NEMA outlet models
Daisy chain up to 15 additional stations for up to 192 (PN5212 / PN7212) or 320 (PN5320 /
PN7320) outlets
2 x 7 segment front panel LED shows Station and Outlet ID
Overcurrent protection and recovery for the PDU
Remote users can monitor outlet status via web pages on their browsers
Safe shutdown support
Separate power for the unit's own power and its power outlets. The user interface is still
accessible even when an overload condition trips the devices' circuit breaker
Remote Access
Remote power control via TCP/IP and a built in 10/100 Ethernet port
Out of Band operation via modem access*
Network Interfaces: TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, ARP, NTP, DNS, Telnet,
10Base-T/100Base-TX, auto sense, Ping
IPv6 support
Operation
Local and Remote power outlet control (On, Off, Power Cycle) by individual outlets and outlet
groups
Outlet group support at the PDU and Daisy-chain levels – the same action can be performed on
a specified group of outlets at the same time
Supports redundant power management via daisy chaining and outlet groups
On/Off scheduling for individual outlets and outlet groups. Power management tasks can be
scheduled on a daily, weekly, monthly, or user-specified times basis
Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power
Power-on sequencing - users can set the power on sequence and delay time for each outlet to
allow equipment to be turned on in the proper order
Easy setup and operation via a browser-based user interface
Multibrowser support (IE, Mozilla, Firefox, Safari, Opera, Netscape)
Telnet and SSH access for text menu configuration and outlet level switching / monitoring
Local console access support
Java GUI AP program provided for non-browser connectivity
RTC support to keep the timer running during times of no power.
Up to 64 user accounts - up to 32 concurrent logins
Management
Power status measurement at PDU and outlet* levels
LED indicators for current; voltage; power dissipation; temperature; and humidity at the PDU
and outlet* levels
Current; voltage; power dissipation; and energy consumption displayed in a browsed-based UI
for monitoring at the outlet*, group, PDU, and daisy-chain levels
Environment monitoring* – supports external temperature/temperature & humidity sensors for
rack temperature and humidity monitoring
Current, voltage, power dissipation, energy consumption, temperature, and humidity threshold
level setting
Alert threshold notification for selected events (On, Off, Recycle, Failure, etc.), via audio alarm
and blinking LEDs (locally), SMTP, SNMP trap notification, and digital output*
Naming support for outlets and outlet groups
User outlet access assignment on an outlet-by-outlet basis.
Windows-based Log Server; event logging, and syslog support
Integration with ALTUSEN CC2000 Management software and KVM devices
API for 3rd party software centralized control integration
Upgradeable firmware – daisy chained stations receive the upgrade via the daisy chain bus
Multi-language support: English, German, Traditional Chinese, Smplified Chinese, Japanese,
Korean, Russian
Security
Three-level password security
IP/MAC filtering
Secure 128-bit SSL encryption
Remote authentication support: RADIUS, TACACS+, LDAP, LDAPS and Active Directory
*Feature supported by PN7212/PN7320 only
Function PN5212 PN5320 PN7212
PN7320
EA1140
• Temperature Sensor
EA1240
• Temperature & Humidity
Sensor
Model
No.
Inlet Inlet Type
PN5212
1
NEMA L5-20P
(120V)
1
IEC 60309
(230V)
PN5320
1
NEMA L5-30P
(120V)
1
IEC 60309
(230V)
PN5212 PN5320 PN7212 PN7320
Amp 20 A 30 A 20 A 30 A16 A 32 A 16 A 32 A
Outlet 12 20 12 20
Inlet
NEMA L5-20P IEC60309 NEMA L5-30P IEC 60309 NEMA L5-20P IEC60309 NEMA L5-30P IEC60309
Rack Space 0U 0U 0U 0U
LAN Port V V V V
Daisy-chain V V V V
Switching Capability Per Outlet Per Outlet Per Outlet Per Outlet
Metering Capability PDU Level PDU Level Outlet & PDU Level Outlet & PDU Level
Thresholds & Alarms V V V V
Environment Monitoring V V
Digital Output Port V V
Modem Support V V
Power
Outlets
Direct 12 20 12 20
Max 192 (via Daisy Chain) 320 (via Daisy Chain) 192 (via Daisy Chain) 320 (via Daisy Chain)
Connectors
Power
Inlets
NEMA 1 x NEMA L5-20P 1 x NEMA L5-30P 1 x NEMA L5-20P 1 x NEMA L5-30P
IEC 1 x IEC 60309 1 x IEC 60309 1 x IEC 60309 1 x IEC 60309
Power
Outlets
NEMA 12 x NEMA 5-15R
3 x NEMA 5-20R
17 x NEMA 5-15R
12 x NEMA 5-15R
3 x NEMA 5-20R
17 x NEMA 5-15R
IEC 12 x IEC320 C13
3 x IEC320 C19
17 x IEC320 C13
12 x IEC320 C13
3 x IEC320 C19
17 x IEC320 C13
PON In / Console 1 x RJ-45 (F)
PON Out 1 x RJ-45 (F)
Modem N/A 1 x RJ-45 (F)
LAN 1 x RJ-45 (F)
Environment Sensor N/A 2 x RJ-11 (F)
Digital Output N/A 1 x Terminal Block
LEDs
ID 1 x 2-digit 7-segment
Station 1 x Green
Outlet N/A 1 x Green
Readout 1 x 3-digit 7-segment
Current 1 x Green
Voltage 1 x Green
Power 1 x Green
Sensor 1 N/A 1 x Green
Sensor 2 N/A 1 x Green
I/P Rating
(Total Input)
NEMA
100-120V; 50/60Hz;
16A
100-120V; 50/60Hz;
24A
100-120V; 50/60Hz;
16A
100-120V; 50/60Hz;
24A
IEC
200-240V; 50/60Hz;
16A
200-240V; 50/60Hz;
32A
200-240V; 50/60Hz;
16A
200-240V; 50/60Hz;
32A
Load Capacity
NEMA
120V; 50/60Hz;
1920W
120V; 50/60Hz;
2880W
120V; 50/60Hz;
1920W
120V; 50/60Hz;
2880W
IEC
230V; 50/60Hz;
3680W
230V; 50/60Hz;
7360W
230V; 50/60Hz;
3680W
230V; 50/60Hz;
7360W
O/P Rating
Per Port
NEMA
100-120V; 50/60Hz;
12A
100-120V; 50/60Hz;
16A (x3) / 12A (x17)
100-120V; 50/60Hz;
12A
100-120V; 50/60Hz;
16A (x3) / 12A (x17)
IEC
200-240V; 50/60Hz;
10A
200-240V; 50/60Hz;
16A (x3) / 10A (x17)
200-240V; 50/60Hz;
10A
200-240V; 50/60Hz;
16A (x3) / 10A (x17)
Total
NEMA
100-120V; 50/60Hz;
15A
100-120V; 50/60Hz;
23A
100-120V; 50/60Hz;
15A
100-120V; 50/60Hz;
23A
IEC
200-240V; 50/60Hz;
15A
200-240V; 50/60Hz;
31A
200-240V; 50/60Hz;
15A
200-240V; 50/60Hz;
31A
Power Consumption
NEMA 120V; 50/60Hz; 16W 120V; 50/60Hz; 22W 120V; 50/60Hz; 16W 120V; 50/60Hz; 22W
IEC 230V; 50/60Hz; 18W 230V; 50/60Hz; 26W 230V; 50/60Hz; 18W 230V; 50/60Hz; 26W
Environment
Operating Temp. 0-5
0℃
Storage Temp. -20 - 60
Humidity 0-80% RH Non-condensing
Physical
Properties
Housing Metal
Weight 4.49 kg 5.68 kg 4.49 kg 5.68 kg
Dimensions
(L x W x H)
6.42 x 5.46 x 134
cm
6.42 x 5.46 x 167.64
cm
6.42 x 5.46 x 134
cm
6.42 x 5.46 x 167.64
cm
© Copyright 2011 ATEN
®
International Co., Ltd.
ATEN and the ATEN logo are trademarks of ATEN International Co., Ltd. All rights reserved. All other trademarks are the property of their respective owners.
Printed 08/2011 V2.0
ATEN International Co., Ltd.
3F., No.125, Sec. 2, Datong Rd., Sijhih District., New Taipei City 221, Taiwan
Phone: 886-2-8692-6789 Fax: 886-2-8692-6767 www.aten.com E-mail: [email protected]
*KVM Over the NET™
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - PN5212/PN5320/PN7212/PN7320

PN5212/PN5320/PN7212/PN7320FEATURESPower Over the NET™Power Distribution UnitsBenefitsWith PDU/Outlet level metering, IT administrators can easily mon

Page 2

PN5212/PN5320/PN7212/PN7320FEATURESPower Over the NET™Power Distribution UnitsBenefitsWith PDU/Outlet level metering, IT administrators can easily mon

Page 3

PN5212/PN5320/PN7212/PN7320FEATURESPower Over the NET™Power Distribution UnitsBenefitsWith PDU/Outlet level metering, IT administrators can easily mon

Page 4 - *KVM Over the NET™

p4The PDU permits server room administrators to set custom thresholds for current, voltage, power consumption, humidity, and temperature. When levels

Page 5 - Specification

p5SpecificationFunction PN5212 PN5320 PN7212PN7320Power Outlets Direct 12 20 12 20Max 192 (via Daisy Chain) 320 (via Daisy Chain) 192 (via Daisy Cha

Page 6

PN5212/PN5320/PN7212/PN7320FEATURESPower Over the NET™Power Distribution UnitsBenefitsWith PDU/Outlet level metering, IT administrators can easily mon

Comments to this Manuals

No comments