Multidrop
A Multidrop configuration is one in which more than two devices
are linked for communication using several IC-485S / IC-485SI
units.
One of the devices that one of the IC-485S / IC-485SIs connects
to is designated as the Master device. All the remaining devices
that the rest of the IC-485S / IC-485SIs connect to are designated
as Slave devices. There are two configurations: Multidrop Full
Duplex, and Multidrop Half Duplex.
1. Multidrop 4 Wire Full Duplex
Multidrop Full Duplex uses reverse four wire cabling to link
all the connected IC-485S / IC-485SI units:
For all IC-485S / IC-485SI units, set SW1 to DCE or DTE
depending on what type of device the IC-485S / IC-485SI
will plug into (if it will plug into a DCE device, configure it
for DTE, and vice versa).
For the Master unit, set SW2 to TxON, RxON.
For all Slave units, set SW2 to TxRTS, RxON.
Master
T+
T
-
R
-
R+
Slave 1
R+
R -
T -
T+
Slave 2
R+
R -
T -
T+
.
.
.
Slave 31
PC1
COM1/
COM2
PC2
COM1/
COM2
PC3
COM1/
COM2