DCE / DTE Connection Table
Because of the polarity of the communication signals, a DTE configured device must connect to a
DCE configured device. The shaded area in the figure below is an example of a DTE to DCE
connection:
Self Test
To test tthe internal circit of the interface converter, connect a dumb terminal to the unit and do the
following:
Set SW1 to DCE (if the dumb terminal is configured for DCE.1.
Set SW2 to TxON, RxON.2.
Connect a wire from pin 1 (Tx+) to pin 4 (Rx+)3.
Connect a wire from pin 2 (Tx-) to pin 3 (Rx-)4.
Set the terminal to full duplex and enter data.5.
If the data displays on the screen, the internal circuit is operational.