19
Auto Scanning
The CS1762 / CS1764A’s Auto Scan feature automatically cycles the KVM
focus through the computer ports at regular intervals. This allows you to
monitor the computer activity without having to take the trouble of switching
from port to port manually. See the table below for details.
Note: 1. The n stands for the number of seconds that the CS1762 / CS1764A
should dwell on a port before moving on to the next. Replace the n
with a number between 1 and 99 when entering this hotkey
combination.
2. While Auto Scan Mode is in effect, ordinary keyboard and mouse
functions are suspended – only Auto Scan Mode compliant
keystrokes and mouse clicks can be input. You must exit Auto Scan
Mode in order to regain normal control of the console.
3. Although the video focus switches from port to port, the keyboard,
mouse, and USB focus doesn’t switch. They stay at the port they were
on when Auto Scanning started.
4. To exit Auto Scan Mode, press the Esc key or the Spacebar.
Hotkey Action
[Scroll Lock] [Scroll
Lock] [A] [Enter]
Invokes Auto Scan. The KVM focus cycles from port to port
at 5 second intervals. Five second intervals is the Default
setting.
[Scroll Lock] [Scroll
Lock] [A] [n] [Enter]
The KVM focus cycles from port to port at n second intervals.
Page view 26