SN3101 User Manual
36
Port Property Settings:
The meanings of the property settings are given in the following table:
(Continues on next page.)
Setting Meaning
Port ID Each port on SN series devices has a port ID number. The value in
this field indicates the port that is being configured. Since the
SN3101 only has one port, the value is COM1.
Port Name You can give a port an appropriate name by editing the Port Name
field.
Interface Select the type of serial interface for the port. Choices are RS-232;
RS-422; RS-485 (2 Wire).
Baud Rate This sets the port’s data transfer speed. Choices are from 300—
460800 (drop down the list to see them all). Set this to match the
baud rate setting of the connected device. Default is 9600 (which
is a basic setting for many serial devices).
Data Bits This sets the number of bits used to transmit one character of
data. Choices are: 5, 6, 7 and 8. Set this to match the data bit
setting of the connected device. Default is 8 (which is the default
for the majority of serial devices).
Parity This bit checks the integrity of the transmitted data. Choices are:
None; Odd; Even; Mark; Space. Set this to match the parity setting
of the connected device. Default is None (which is the default for
the majority of serial devices).
Stop Bits This indicates that a character has been transmitted. Set this to
match the stop bit setting of the connected device. Choices are: 1,
1.5, and 2. Default is 1 (which is the default for the majority of
serial devices).
Flow Control This allows you to choose how the data flow will be controlled.
Choices are: None, Hardware (RTS/CTS), and XON/XOFF. Set
this to match the flow control setting of the connected device.
Default is None.
Enable Toggle
DTR
Enabling this parameter allows the DTR signal to toggle between
disabled and enabled when the port is occupied. Choices are: No,
and Yes. Default is No.
Note: For some devices, in order for Enabled to work correctly,
you must first disable DTR (select No, then click Update), then
Enable it (select Yes, then click Update).
Online Detect This allows you to set the DSR signal to detect online status or not.
Choices are: None and DSR. Default is DSR.